Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq Bras Endocrinol Metabol ; 53(4): 425-8, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19649379

RESUMO

INTRODUCTION: Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE: We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS: The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS: Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS: These data suggest that dawn calibration does not alter accuracy of method.


Assuntos
Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Ritmo Circadiano , Diabetes Mellitus/sangue , Adolescente , Adulto , Automonitorização da Glicemia/normas , Calibragem , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Adulto Jovem
2.
Arq. bras. endocrinol. metab ; 53(4): 425-428, jun. 2009. graf, tab
Artigo em Inglês | LILACS | ID: lil-520766

RESUMO

INTRODUCTION: Continuous glucose monitoring system is a valuable instrument to measure glycemic control, which uses a retrospective calibration based upon 3 to 4 capillary glucose meter values inserted by the patient each day. OBJECTIVE: We evaluated the interference of calibration during the dawn period in the system accuracy. METHODS: The monitoring data were retrospectively divided into two groups: with (Group A) or without (Group B) the dawn period calibration (between 1:00 and 5:00 AM). Accuracy of the method was expressed by relative absolute difference. RESULTS: Thirty-four continuous glucose monitoring data were evaluated comprising a total of 112 nights. A total of 289 paired readings were analyzed - 195 in Group A and 94 in Group B. We did not find a difference in relative absolute difference (RAD%) in any analyzed period of day by adding dawn calibration. CONCLUSIONS: These data suggest that dawn calibration does not alter accuracy of method.


INTRODUÇÃO: O CGMS (sigla do inglês continuous glucose monitoring system) é um instrumento valioso no controle glicêmico e utiliza uma calibração por meio de 3 ou 4 medidas de glicemia capilar inseridas pelo paciente em cada dia do exame. OBJETIVO: Avaliar a interferência da calibração durante a madrugada na acurácia do sistema. MÉTODOS: Os dados das monitorizações foram divididos retrospectivamente em dois grupos: com (Grupo A) ou sem (Grupo B) a calibração da madrugada (entre 1:00 e 5:00 AM). A acurácia do método foi mostrada pela diferença relativa absoluta (DRA por cento). RESULTADOS: Trinta e quarto dados de monitorização foram avaliados em um total de 112 noites. Um total de 289 leituras pareadas foi analisado - 195 no Grupo A e 94 no Grupo B. Não foi encontrada diferença em DRA% em nenhum período do dia quando adicionada a calibração durante a madrugada. CONCLUSÕES: Esses dados sugerem que a calibração da madrugada não altera a acurácia do método.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Automonitorização da Glicemia/métodos , Glicemia/metabolismo , Ritmo Circadiano , Diabetes Mellitus/sangue , Automonitorização da Glicemia/normas , Calibragem , Métodos Epidemiológicos , Fatores de Tempo , Adulto Jovem
3.
Endocr Pract ; 13(3): 219-24, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17599851

RESUMO

OBJECTIVE: To assess how ultrasonography can contribute during the evaluation of a thyroid nodule and whether this technique can have a role in predicting malignant involvement. METHODS: In this retrospective study, data were analyzed on 220 consecutive patients (with 348 thyroid nodules) who underwent thyroidectomy and had previously undergone assessment by high-resolution thyroid ultrasonography. Nodule size, echogenicity, regularity of margins, halo sign, presence or absence of calcifications, and invasion of surrounding tissues were evaluated. The nodules were classified as low, medium, or high risk for malignant involvement on the basis of nodule characteristics found on ultrasonography. All nodules were submitted to cytologic examination by fine-needle aspiration (FNA) before thyroidectomy. Ultrasound, FNA, and pathologic postoperative results were compared. RESULTS: Among the 348 thyroid nodules, 56 were ultrasonographically classified as low risk, 268 as medium risk, and 24 as high risk for malignant potential. Fifty of 56 (89.3%) low-risk nodules and 213 of 268 (79.5%) medium-risk nodules were diagnosed as benign at pathologic postoperative examination. In contrast, however, only 6 of 24 (25%) high-risk nodules were diagnosed as benign. Among the 18 high-risk nodules of 1-cm diameter or larger, FNA showed a 20% false-negative result. CONCLUSION: High-risk classification of a thyroid nodule on ultrasonography had a positive predictive value for malignant involvement of 75%. Nodule characteristics analyzed by ultrasonography should be considered at the time of surgical intervention.


Assuntos
Adenocarcinoma/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Biópsia por Agulha Fina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Nódulo da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/cirurgia , Tireoidectomia , Ultrassonografia
4.
Arq. bras. endocrinol. metab ; 46(3): 249-254, jun. 2002. tab, graf
Artigo em Português | LILACS | ID: lil-313128

RESUMO

OBJETIVO: correlacionar a hipertrigliceridemia pós-prandial com conhecidos fatores de risco para aterosclerose. MATERIAL E MÉTODOS: Foram estudados 47 pacientes não diabéticos (30 mulheres e 17 homens, idade: 40,5 ± 14,9 anos, IMC: 26,1 ± 5,4kg/m2) com trigliceridemia de jejum normal (<200mg/dl). Triglicerídeos, HDL e colesterol total foram medidos nos tempos 0, 3 e 5 horas após ingestão de aproximadamente 70g de gordura (200g de creme de leite a 25 por cento e 2 gemas), sendo então avaliados vários parâmetros. RESULTADOS: Pacientes com pico de triglicerídeos de 3 horas maior que o Segundo- quartil (164,8mg/dl), apesar de triglicerídeos de jejum normais, apresentaram maior IMC (28,1 ± 5,6 vs. 24,2 ± 4,5kg/m2; p= 0,008), maior circunferência abdominal (95,7 vs. 84,1 cm; p= 0,001), maior relação cintura/quadril (0,92 vs. 0,86; p= 0,008), maior pressão diastólica (83,1 vs. 77,2mmHg; p= 0,02) e menor HDL (39,1 vs. 48,3mg/dl; p= 0,008). CONCLUSÕES: A hipertrigliceridemia pós-prandial se correlaciona com vários fatores de risco cardiovascular mesmo em pacientes normotrigliceridêmicos.


Assuntos
Humanos , Masculino , Feminino , Adulto , Arteriosclerose , Hiperlipidemias , Período Pós-Prandial , Fatores de Risco , Angina Microvascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...